Spo2 Max30102 Blood Oxygen Concentration

₨ 567

- +

The MAX30102 Blood Oxygen Sensor Module is a high-performance device for measuring heart rate and blood oxygen saturation. With its integrated red and infrared LEDs, photodetector, and advanced algorithms, the MAX30102 provides accurate and reliable readings.

Key Features:





Accurate Heart Rate and Blood Oxygen Measurement: Monitor vital health metrics with precision.



Low Power Consumption: Suitable for battery-powered devices.



I2C Interface: Easily integrate with microcontrolle for data collection and analysis.



Ambient Light Suppression: Ensures accurate readings even in challenging lighting conditions.



Durable Construction: Built to last for long-term use.



Upgrade your health monitoring projects with the MAX30102 Blood Oxygen Sensor Module and gain valuable insights into your health.



 

Code:





#include

#include “MAX30105.h”

MAX30105 particleSensor; // initialize MAX30102 with I2C

void setup()

{

  Serial.begin(115200);

  while(!Serial); //We must wait for Teensy to come online

  delay(100);

  Serial.println(“”);

  Serial.println(“MAX30102”);

  Serial.println(“”);

  delay(100);

  // Initialize sensor

  if (particleSensor.begin(Wire, I2C_SPEED_FAST) == false) //Use default I2C port, 400kHz speed

  {

    Serial.println(“MAX30105 was not found. Please check wiring/power. “);

    while (1);

  }

  byte ledBrightness = 70; //Options: 0=Off to 255=50mA

  byte sampleAverage = 1; //Options: 1, 2, 4, 8, 16, 32

  byte ledMode = 2; //Options: 1 = Red only, 2 = Red + IR, 3 = Red + IR + Green

  int sampleRate = 400; //Options: 50, 100, 200, 400, 800, 1000, 1600, 3200

  int pulseWidth = 69; //Options: 69, 118, 215, 411

  int adcRange = 16384; //Options: 2048, 4096, 8192, 16384

  particleSensor.setup(ledBrightness, sampleAverage, ledMode, sampleRate, pulseWidth, adcRange); //Configure sensor with these settings

}

void loop() {

  particleSensor.check(); //Check the sensor

  while (particleSensor.available()) {

      // read stored IR

      Serial.print(particleSensor.getFIFOIR());

      Serial.print(“,”);

      // read stored red

      Serial.println(particleSensor.getFIFORed());

      // read next set of samples

      particleSensor.nextSample();      

  }

}





Second code:

 

/*

  Optical Heart Rate Detection (PBA Algorithm) using the MAX30105 Breakout

  By: Nathan Seidle @ SparkFun Electronics

  Date: October 2nd, 2016

  https://github.com/sparkfun/MAX30105_Breakout

  This is a demo to show the reading of heart rate or beats per minute (BPM) using

  a Penpheral Beat Amplitude (PBA) algorithm.

  It is best to attach the sensor to your finger using a rubber band or other tightening

  device. Humans are generally bad at applying constant pressure to a thing. When you

  press your finger against the sensor it varies enough to cause the blood in your

  finger to flow differently which causes the sensor readings to go wonky.

  Hardware Connections (Breakoutboard to Arduino):

  -5V = 5V (3.3V is allowed)

  -GND = GND

  -SDA = A4 (or SDA)

  -SCL = A5 (or SCL)

  -INT = Not connected

  The MAX30105 Breakout can handle 5V or 3.3V I2C logic. We recommend powering the board with 5V

  but it will also run at 3.3V.

*/

#include

#include “MAX30105.h”

#include “heartRate.h”

MAX30105 particleSensor;

const byte RATE_SIZE = 4; //Increase this for more averaging. 4 is good.

byte rates[RATE_SIZE]; //Array of heart rates

byte rateSpot = 0;

long lastBeat = 0; //Time at which the last beat occurred

float beatsPerMinute;

int beatAvg;

void setup()

{

  Serial.begin(115200);

  Serial.println(“Initializing…”);

  // Initialize sensor

  if (!particleSensor.begin(Wire, I2C_SPEED_FAST)) //Use default I2C port, 400kHz speed

  {

    Serial.println(“MAX30105 was not found. Please check wiring/power. “);

    while (1);

  }

  Serial.println(“Place your index finger on the sensor with steady pressure.”);

  particleSensor.setup(); //Configure sensor with default settings

  particleSensor.setPulseAmplitudeRed(0x0A); //Turn Red LED to low to indicate sensor is running

  particleSensor.setPulseAmplitudeGreen(0); //Turn off Green LED

}

void loop()

{

  long irValue = particleSensor.getIR();

  if (checkForBeat(irValue) == true)

  {

    //We sensed a beat!

    long delta = millis() – lastBeat;

    lastBeat = millis();

    beatsPerMinute = 60 / (delta / 1000.0);

    if (beatsPerMinute < 255 && beatsPerMinute > 20)

    {

      rates[rateSpot++] = (byte)beatsPerMinute; //Store this reading in the array

      rateSpot %= RATE_SIZE; //Wrap variable

      //Take average of readings

      beatAvg = 0;

      for (byte x = 0 ; x < RATE_SIZE ; x++)

        beatAvg += rates[x];

      beatAvg /= RATE_SIZE;

    }

  }

  Serial.print(“IR=”);

  Serial.print(irValue);

  Serial.print(“, BPM=”);

  Serial.print(beatsPerMinute);

  Serial.print(“, Avg BPM=”);

  Serial.print(beatAvg);

  if (irValue < 50000)

    Serial.print(” No finger?”);

  Serial.println();

}

Weight 1 kg
Dimensions 2 × 2 × 2 cm